Availability: | |
---|---|
Quantity: | |
MGPM
1. When the load changes during work, a cylinder with sufficient output power should be selected.
2. Under high temperature or corrosive conditions, a corresponding high temperature resistant or corrosion resistant cylinder should be selected.
3. In places with high humidity, dust, or water droplets, oil dust, or welding slag, the cylinder should take corresponding protective measures.
4. Before the cylinder is connected to the pipeline, debris in the pipeline must be removed to prevent debris from entering the cylinder.
5. The medium used in the cylinder should be filtered through a source core of more than 40um before use.
6. The directional load on the cylinder during operation should not exceed the allowable value to maintain the normal operation and service life of the cylinder.
7. Under low circulation conditions, anti-freeze measures should be taken to prevent the water in the system from freezing.
8. When the cylinder is removed and not used for a long time, attention should be paid to surface rust prevention. Anti-clogging caps should be added to the inlet and exhaust ports. Due to the product manufacturing With high guide precision, please do not disassemble the cylinder peripheral block or cylinder head by yourself.
Bore size(mm) | 12 | 16 | 20 25 | 32 | 40 | 50 | 63 | 80 | 100 |
Fluid | Air | ||||||||
Action | Double acting, single rod | ||||||||
Minimum | 0.12 Mpa |
| |||||||
Maximum | 1.0 Mpa | ||||||||
Proof pressure | 1.5 MPa | ||||||||
Ambient and | -20 to 80℃(No freezing) | ||||||||
Cushion | Rubber bumpe | ||||||||
Lubrication | Non-lube | ||||||||
Port size | M5×0.8 | 1/8 | 1/4 | 3/4 |